CONTENTS
#contents
----
Lastmodified &lastmod;
----
*MegaRaid_SAS_9271_8i [#q0fed61a]

ヒートシンクのピンが外れていて、壊れて(熱破壊?)しまった「MegaRaid_SAS_9271_8i」を更新したところ、OS起動時から、ビープ音がなりっぱなし。
ヒートシンクのピンが外れていて、壊れて(熱破壊?)しまった「MegaRaid_SAS_9271_8i」を更新したところ、OS起動時から、ビープ音(アラーム音)が鳴り続ける状態。

LSI MegaRAID Card Beep Codes 

Table 5-3 Summary of LSI MegaRAID Card Beep Codes

,Beep Code,LSI Firmware State,Cause (Depending on RAID Level) 
,3 秒 on 1 秒 off,SPEAKER_OFFLINE_ENTRY,• RAID 0: One or more drives offline.
,,,• RAID 1: Two drives offline.
,,,• RAID 5: Two or more drives offline.
,,,• RAID 6: More than two drives offline.
,1 秒 on 1 秒 off,SPEAKER_DEGRADED_ENTRY,• RAID 1: A mirrored drive failed.
,,,• RAID 5: One drive failed.
,,,• RAID 6: One or two drives failed.
,1 秒 on 3 秒 off,SPEAKER_HOTSPARE_ENTRY,A hot spare drive has completed the rebuild process and has been brought into the array.

 


 


だけど、GUIなMegarade Strage Managerでは、異常なし、の状態。何故、アラームが鳴っているのかが不明・・・。

「MegaRaid SAS 9271 8i アラーム」でググルと、

http://www.newtech.co.jp/support/products/cloudy2_nas_ws/pdf/RAID_Contorolle_setup.pdf

こんなコンテンツに・・・。2013/11/12付けのドキュメントには、

 本手順書は、RAID コントローラの出荷時初期値の変更に伴い、推奨設定値のご案内および設定変更手順について記載したものです。
 設定変更項目は、PatrolRead、ConsistencyCheck、コピーバックです。
 
 ・対象 RAID コントローラ :LSI MegaRAID SAS 9260-4i , LSI MegaRAID SAS 9271-4i/8i 
 (ファームウェアバージョンに関係なく 9260、9271 のコントローラが対象になります。)

で、

 3.コピーバックの設定変更について
 コピーバック設定を無効にすることをお勧めします。本設定変更は、ある条件においてアラーム音が鳴り
 続ける事象に対する処置となります。

ということで、

http://www.lsi.com/products/raid-controllers/pages/megaraid-sas-9271-8i.aspx

から、_StorCLIをダウンロードしてきて、以下を実行。



 D:\Downloads\Raid_Card\1.13.06_StorCLI_u1\storcli_all_os\Windows>storcli64.exe show
 Status Code = 0
 Status = Success
 Description = None
 
 Number of Controllers = 1
 Host Name = RAMPAGE4F
 Operating System  = Windows 7
 
 System Overview :
 ===============
 
 -----------------------------------------------------------------------------------
 Ctl Model                 Ports PDs DGs DNOpt VDs VNOpt BBU  sPR DS  EHS ASOs Hlth
 -----------------------------------------------------------------------------------
   0 LSIMegaRAIDSAS9271-8i     8   8   1     0   1     0 Msng On  1&2 Y      2 Opt
 -----------------------------------------------------------------------------------
 
 Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
 PDs=Physical drives|DNOpt=DG NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
 Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
 sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Hot Spare
 Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit
 Hlth=Health|Safe=Safe-mode boot
 
 
 
 D:\Downloads\Raid_Card\1.13.06_StorCLI_u1\storcli_all_os\Windows>
 D:\Downloads\Raid_Card\1.13.06_StorCLI_u1\storcli_all_os\Windows>storcli64.exe /c0 set copyback=off type=all
 Controller = 0
 Status = Success
 Description = None
 
 
 Controller Properties :
 =====================
 
 ----------------
 Ctrl_Prop Value
 ----------------
 Copy Back ALL
 ----------------
 
 
 
 D:\Downloads\Raid_Card\1.13.06_StorCLI_u1\storcli_all_os\Windows>


----